Hayward pool heater lo - •Only qualified technicians should service heater •Replace damaged wiring immediately •Ensure appliance is properly ... "LO: Code 44-47 Change/Replace Combustion Chamber 20-26 12. "IF" Code 48-49 ... The default Max temp set points are 90ºF (Pool) 104ºF (Spa). When setting the max temp lock-out set point, the LEDs & display should ...

 
 Show pool professionals that sell/service these specific products (restricts search to include only companies that sell/service each item checked): . Snap benefits sc

Hayward H300FDP Pdf User Manuals. View online or download Hayward H300FDP Owner's Manual, Troubleshooting Manual ... Brand: Hayward | Category: Swimming Pool Heater | Size: 6.96 MB Table of Contents. Table of Contents. 2 ... LO" Code. 46. Pressure Switch Adjustment. 49. IF" Code. 52. AC" Code. 57. AO" Code. 58.NOTE: The default Max temp lock-out set points are 90ºF (Pool) 104ºF (Spa). 14; Hayward H400FDN | Universal H Series Troubleshooting Guide - Page 15 ... Verify the pump is running & adequate water is flowing through heater. "LO" is NORMAL when the pump is turned off. Inspect water pressure switch Step 11A Continuity test Step 11B Inspect the ...Dec 6, 2020 ... ... heater to a Hayward ... Hayward Universal H-Series Pool Heater Installation - AmeriMerc.com ... Heater Video for DISABLE " bo" which BYPASS ...The Universal H-Series Heater is the world-class heater with an Earth-friendly conscience. While all Hayward H-Series heaters are energy-efficient, the Universal H-Series Low NOx heater has an 83-84 percent industry-leading thermal efficiency and complies with all current California and Texas air quality emission standards.POOL HEATER TEMPERATURE 🔐 UNLOCK !!! HAYWARD ,may work for different models,H250FDNASME, H250FDPASME, H400FDNASME, and H400FDPASME. H135ID1, and H135IDP1. Water Pressure Switch Replacement Procedure. FDXLWPS1930 for Universal H-Series (Forced-Draft) Heaters. This kit is intended to be used only with Hayward Universal H-Series (forced-draft) gas heater models. These heaters may be.The Hayward pool heater spa mode is designed to maintain a specific “spa-like” temperature in the pool. To use this mode, enable “Spa mode” from the control panel, set the required temperature, and let the pool heater warm the water. Once ready, test the water. This process is a joy to behold for those who want to soak themselves in ...Universal H-Series Propane Gas 300,000 BTU Low NOx (Expert Line) Item #H300FDP. EXPERT LINE products are only available through your local pool professional. The Universal H-Series is an energy efficient, high performance, installation adaptable commitment to the pool service professional. Standard cupro nickel heat exchanger.Hayward - Front Header Assembly. SKU: 614836. Details: FRONT HEADER ASS'Y. Availability: In Stock. $569.99. Add to Cart. Keep your pool equipment running strong with Hayward H-Series H250IDL2 - H400IDL2 Low NOx Pool Heater Parts.Here you’ll gain easy access to information regarding your favorite Hayward products. Whether you are looking for a Quick Reference Guide, ... Learn about maintenance, innovation, pool safety & other insights from Hayward. Explore. Tools. Utilize tools and downloads of mobile apps ... Universal H Series and ASME Gas Heater Installation, ...Swimming Pool Heater Hayward H200FD Service & Installation Manual. Pool and spa/hot tub heaters (64 pages) Swimming Pool Heater Hayward H250FD Owner's Manual. ... 11. Service LED ON: “LO” Code Check continuity of Is water pressure Verify adequate water pressure “LO” Code switch wiring free of water flow, is switch, ...What Does LO Code Mean On The Pool Heater? Hayward Pool Heater LO Code [Reasons + Solutions] 1. Water Temperature Switch Malfunction. 2. Defective Vent Pressure …A Answered on 1/17/2013 by InyoPools Product Specialist Patrick P.. For the Hayward Lo Nox heater, you would not need to purchase an additional vent if you are using it outside. If you are installing the heater outside, we recommend you purchasing a heater cover.1. First, check that your filter pump is On. Next, ensure the heater is enabled and the set point is higher than the current water temperature. Select the bow to water. Press the heater tile to enter the heater's menu. 2. Ensure the heater is enabled and the set point is higher than the current water temperature.In this video you'll see how a natural gas pool heater is wired and how the wiring is covered from 240 volts (double pole) to 120 volts (single pole). Also, ...May 3, 2007 16,110 Pleasanton, CA Pool Size 20000 Surface Plaster Chlorine Salt Water Generator SWG Type Hayward Aqua Rite (T-15)4. 5. Explore Hayward's pool parts and accessories for maintenance and upgrades. Find high-quality replacements, equipment, and supplies to enhance your pool experience.Program Heater Bypass & Temperature Lockout 13-15 Test/Adjust Gas Pressure 16-17 ... “LO” ode 46-51 12. “IF” ode 52-55 13. “A” ode 56-57 14. ... The default Max temp lock-out set points are 90ºF (Pool) 104ºF (Spa). Press the MENU I ON button to place the heater in STANDY mode.The Hayward Universal H-Series gas heater is one of the most energy-efficient Pool and Spa heating solutions on the market! Its ground-breaking hydraulic design reduces pump circulation run time, giving you an energy savings of up to 18%! This unit is perfect for the environmentally conscious Pool and Spa owner thanks to its Low NOx ... All HAYWARD Pool Heaters can be shipped to you at home. What are some of the most reviewed products in HAYWARD Pool Heaters? Some of the most reviewed products in HAYWARD Pool Heaters are the HAYWARD Universal H-Series Propane Gas 150,000 BTU Low NOx Pool Heater with 5 reviews, and the HAYWARD Universal H-Series Natural Gas 400,000 BTU Low NOx ... Apr 3, 2023 · Many choose Hayward pool heaters to keep their pool water comfortable and warm. However, sometimes these heaters can experience issues that require a reset. To reset your Hayward pool heater, you’ll need to turn off the power, wait a few minutes, and then turn it back on again. This simple process can resolve many common […] Jun 24, 2022 ... 10+ year old Hayward pool heater with multiple safety switches bypassed. What were they thinking?? Interested in an easy to use mobile ...Hayward Pool Products Inc is a leading manufacturer of high-quality pool equipment, including pumps, filters, heaters, and cleaners. If you’re lucky enough to own one of their prod...HeatPro Variable-Speed Heat-Cool Pump 120k BTU. Heating swimming pools is a wise investment as it increases its value and extends the swimming season. So to graduate to a higher degree of comfort and control, choose a Hayward heating solution.16. HAXHLI1930. Hi Limit 135 Degree F (used On Heaters made after 10/28/2000) HE-05495. BUY ME. 17. HAXHLI2932. Hi Limit 160 Degree F.Jun 22, 2016 ... From https://www.swimmingpoolsteve.com/pages/heater-break.html - If you have a problem with your pool heater in that it will not fire or ...Hayward Universal H-Series Pool Heater - 250,000 BTU Propane . $3,179.99. SKU. W3H250FDP. Icon Label Description Type Size Download; Hayward H-Series Universal Heater Brochure: Hayward H-Series Universal Heater: pdf: 1.3 MB: Download: Qty. Add to Cart. Add to Compare. 250,000 BTU Propane . Skip to the end of the images gallery. HeatPro In Ground Heat Pump, 140,000 BTUs, Square Platform. Hayward has an advanced lineup of gas heat and electric heat and heat+chill solutions to deliver the ultimate control of your water temperature. The Hayward Universal H-Series gas heater is the “universal” energy efficient remedy for any new or existing pool or spa. An industry leading hydraulic design reduces circulation pump run time to provide energy savings of up to 18% when compared to …TOP VENT PRO-INVERTER 13.5kW. SKU: PASRW030PUBP. Add to Compare. Showing 1-12 of 22. 1. 2. Heating swimming pools is a wise investment as it increases its value and extends the swimming season. So to graduate to a higher degree of comfort and control, choose a Hayward pool heater.We have a commercial inground pool with a 250000 btu Hayward H Series Propane Heater for the spa and we just added a 140k Hayward Heat Pro Heat pump to pool. How can we plumb them together so both poo …The possible causes behind this error message are- a dirty pool filter, water pressure switch fault, vent pressure switch fault, temperature limit switch fault, and exhaust gas …Answering a viewers request on how to add and program a newly installed heater to a Hayward OmniLogic Automation system. Dive in with a dealer near you. Our network of certified personnel can help you build your pool, recommend a product, repair a faulty product, and test your water. Find a professional near you. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools. How to fix it: Check that pool pump is receiving enough water. Ensure that your pool pump is sending water to the heat pump. For variable speed pool pumps, try putting the pump speed up a notch Check for any clogs or backups causing poor water circulation. The same is true if what you use is in your pool is the Raypak pool heater.INNOVATION MADE EASY. Hayward Commercial Aquatics offers a full range of industry-leading innovative products designed to work together as one total system to help every commercial pool perform at its absolute best. Our products set the technological standard while providing unmatched performance, efficiency, reliability, versatility and ease ... HeatPro Heat Pump 140k BTU. Hayward. SKU: HP21404TC. High performance, energy-efficient HeatPro heat pumps quietly and economically maintain the ideal water temperature at all times. Add to Compare. Add to Export. Overview. Specifications. Hayward Equipment H2Oasis Pools is proud to be a Hayward Authorized Service Center and offer a wide variety of Hayward products including pumps, filters, heaters, cleaners, lights, sanitization and controls. Our professional pool technicians are certified to install and repair all Hayward products and answer any service-related questions.April 9, 2023 by William. Hayward pool heater IF code basically signifies the ignition failure of your heater system. The major reasons for Hayward pool heater code IF/ignition failure include lower gas supply, clogged filter, and malfunctioning of the gas and plumber valve. Also, a faulty transformer, defective flame sensor, bad igniter, and ... HeatPro Heat Pump 140k BTU. Hayward. SKU: HP21404TC. High performance, energy-efficient HeatPro heat pumps quietly and economically maintain the ideal water temperature at all times. Add to Compare. Add to Export. Overview. Specifications. Change the sand in a Hayward sand filter by washing the old sand through the drain plug using a garden hose and then replacing it with 300 pounds of 20-mesh swimming pool filter sa...Dec 21, 2023 · Key Takeaways. The P5 code on Hayward pool heaters indicates a problem with the pressure switch. Common causes of the P5 code include clogged filters, improper water flow, and electrical issues. Troubleshooting steps for the P5 code involve checking water pressure, inspecting the heat exchanger, and verifying the gas supply. Service LED ON: “LO” Code “LO” Code (Limit Open) may relate to water flow. Verify the pump is running & adequate water is flowing through heater. “LO” is NORMAL when the …Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. Gain insight. ... Phase Heaters: 1.0000: Platform: Square: Pool Type: In Ground: Product Dimensions: 37 " x 30.5 " x 33.6 "Product Height: 37 in: Product Length: 33.6 in: Product Weight: 230 lb:Hawyard H400 Heater "LO" flashing. Thread starter TNorth225; Start date Apr 21, 2009; Jump to latest Follow Reply Forums. Equipment - Build ... I recently bought a house with a in ground pool/hot tub combo that includes a Hayward H400 pool heater. It was a bank owned house where the pool had been sitting without filtering for ...The Hayward Heater HS code indicates that either your water temperature has exceeded a maximum of 104°F or the water temperature is changing at an unusual rate (faster than 6°F in 60 seconds or less while the heater) is on and firing.Detailed Product Description. W3H250FDP previously H250FDP. For Altitudes Up To 3,048 Meters (10,000 Feet) Product Name: Hayward Universal H Series Low NOx 250,000 BTU Propane Swimming Pool Heater. Product Code: W3H250FDP. Maximum Altitude: 10,000 FT.The possible causes behind this error message are- a dirty pool filter, water pressure switch fault, vent pressure switch fault, temperature limit switch fault, and exhaust gas temperature limit fault. Read our guide on how to fix the LO code on the Hayward heater to get your heater running ASAP.HI My Hayward Hseries pool heater shows a LO and stops working when it rains. My temp dropped from 92 to 80. Contractor's Assistant: Who manufactured the pool? I can't recall. It is a semi-inground purchased through Great Escape 5 years ago. Heater is 5 years old. I replaced the heating tubes last summer.Professional Service: If you’ve tried the above steps and the LO code persists, it’s advisable to contact a professional pool heater technician. They can diagnose the issue more accurately and perform any necessary repairs. Preventing Future LO Codes. To avoid encountering the Hayward Heater LO Code in the future, consider …Pool heater question. This is a raypak pool heater manifold. Have a water sw open code. Where’s the switch. There two sets of wires running to probes. Ones a thermometer and the other is this little brass plug with two terminals coming off it. I’ve removed it and it’s not a switch. Thoughts ?What Is My Hidden Talent. Flat Creek Lodge Hayward. 10290 Highway 27 South, Hayward, WI 54843.Enter Dates. From $135. Check In. 15 00. Check Out. 15 00.. Browse and compare Hayward motels when you search with Expedia. Read reviews, search by map, and book the best motels in Hayward that suit your needs with …The Lo on a Hayward heater means “low.” When the Lo setting is selected, the heater runs at a lower speed, which can help conserve energy. In some cases, the Lo setting may indicate a malfunction or another issue with the heater. If you notice your Hayward heater displaying an LO code, it is important to check the manual or contact …H Series Low NOx 200K Pool Heater Natural Gas. HEATER-UNIVERSAL 150K NATURAL LONX. Hayward H-Series LO NOx Heater 250,000 BTU Natural Gas. Hayward H-Series LO NOx Heater 250,000 BTU Propane Gas. Hayward H-Series LO NOx Heater 350,000 BTU Propane Gas. Hayward H-Series LO NOx Heater 400,000 BTU Natural Gas. …Jul 19, 2023 · May 3, 2007 16,110 Pleasanton, CA Pool Size 20000 Surface Plaster Chlorine Salt Water Generator SWG Type Hayward Aqua Rite (T-15) Oct 3, 2017 ... My Hayward H100ID stopped heating the swimming pool water. I spent 3 afternoons and evenings of my free time pulling my hair out trying to ...I recently bought a house with a in ground pool/hot tub combo that includes a Hayward H400 pool heater. It was a bank owned house where the pool had been sitting without filtering for probably 6 months. After getting everything cleaned up, having the system gone through, I fired it up and the...Tel: 08-355-75 www.hayward-pool.com USE ONLy HAyWARD GENUINE REPLACEMENT PARTS SAFETy INFORMATION 3 Basic safety precautions should always be followed, including the following: Failure to follow instructions can cause severe injury and/or death. This is the safety-alert symbol. When you see this symbol on your …Universal H-Series Natural Gas 400,000 BTU Low NOx. Hayward. SKU: W3H400FDN. The Universal H-Series is an energy efficient, high performance, installation adaptable commitment to the pool service professional. Add to Compare. Add to Export.The Universal H-Series Low NOx heater has an 84 percent industry-leading thermal efficiency and complies with all current California air quality emission standards. The low NOx emission makes it a perfect choice for the environmentally concerned pool owner. Enjoy a warmer pool this season without your fuel costs skyrocketing.Electric – the energy where this heater comes from is through electricity. An electric heater is usually made of an electrical resistor, and it works throughout the principle of Joule Heating. Solar – Through the help of the sun’s heat and solar panels, the water heats, then the water from the pool has been pumped into the panels. It is heated before throwing it …May 6, 2021 ... How to Repair The Hayward H Series Heater by replacing the Heat Exchanger and Control Panel DIY. The Hayward H series pool heaters have a ...Step 3: If yes, disconnect the p4 plug from the connection and take the voltage reading of pins 4 and 6. Here you will also get reading for 110-125 VAC. Step 4: In case you are getting the right voltage in both cases, it’s a must say that the fuse is blown and you need to replace it.Locate a dealer near you for all your needs: building or servicing your pool, buying a product, or warranty support.1.3 Heater Cycling On And Off. 2 Troubleshooting Steps. 2.1 Check Gas Pressure And Fuel Supply. 2.2 Inspect Air Supply And Venting. 2.3 Ensure Proper Water Flow. 2.4 Clean Filters And Pump. 2.5 Adjust External Bypass If Needed. 3 Tips For Diagnosing Problems. 3.1 Follow The Heater Start Sequence.Aug 22, 2022 ... A super easy fix for a stuck button on a Hayward pool heater. Pool Heater Replacement Control Panel Keypad Membrane Switch Compatible with ...Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. Gain insight. ... Phase Heaters: 1.0000: Platform: Square: Pool Type: In Ground: Product Dimensions: 37 " x 30.5 " x 33.6 "Product Height: 37 in: Product Length: 33.6 in: Product Weight: 230 lb:Swimming Pool Heater Hayward H200FD Service & Installation Manual. Pool and spa/hot tub heaters (64 pages) Swimming Pool Heater Hayward H250FD Owner's Manual. ... 11. Service LED ON: “LO” Code Check continuity of Is water pressure Verify adequate water pressure “LO” Code switch wiring free of water flow, is switch, ...Find a professional near you. Find a dealer. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and …I have Hayward H150FDN Universal H-Series, Low NOx, 150,000 BTU, Natural Gas, Pool and Spa Heater and I am getting a LO code with is a flow problem. I have my intermatic timer set for 755am to turn on and give my equipment power, then at 8am the Hayward pump turn on.The Hayward Universal H-Series gas heater is one of the most energy-efficient Pool and Spa heating solutions on the market! Its ground-breaking hydraulic design reduces pump circulation run time, giving you an energy savings of up to 18%! This unit is perfect for the environmentally conscious Pool and Spa owner thanks to its Low NOx ...If it’s primed and pumping and you have LO clean your filter cartridge. If that doesn’t work run the system with the cartridge removed and see if it it fires. If it does buy a new cartridge. If it still doesn’t work call Hayward cuz you could have a bad a pressure/flow sensor. 2.PitschPlumbing. Generally, LO refers to the pressure switch, water pressure. This can be caused by either the diaphram in the flow switch has failed or the filters is clogged and/or pump is unable to make enough pressure to make the switch. Open the front panel of the heater and look up in to the right. You will see a round part with 2 wires ...Sep 22, 2018 ... My pool heater stopped working and the display showed IO which means the igniter is bad. It was replaced and still showed that code.The Hayward pool heater spa mode is designed to maintain a specific “spa-like” temperature in the pool. To use this mode, enable “Spa mode” from the control panel, set the required temperature, and let the pool heater warm the water. Once ready, test the water. This process is a joy to behold for those who want to soak themselves in ...Hayward salt systems are a popular choice for homeowners looking to maintain their swimming pool water in a clean and safe condition. These systems use salt to generate chlorine, e... Show pool professionals that sell/service these specific products (restricts search to include only companies that sell/service each item checked): PitschPlumbing. Generally, LO refers to the pressure switch, water pressure. This can be caused by either the diaphram in the flow switch has failed or the filters is clogged and/or pump is unable to make enough pressure to make the switch. Open the front panel of the heater and look up in to the right. You will see a round part with 2 wires ...Dive into a pool of knowledge with our Hayward Pools manuals and literature page, where you can search by SKU. Explore comprehensive guides, maintenance manuals, and essential literature for all your pool needs. Whether you're a beginner or a seasoned pool owner, find everything you need to keep your Hayward pool in perfect condition. Start …Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. Gain insight. ... Phase Heaters: 1.0000: Pool Type: In Ground: Product Dimensions: 24 " x 25 " x 29.5 "Product Height: 24 in: Product Length: 29.5 in: Product Weight: 165 lb: Product Width: 25 in:First, turn off the power to the pool heater circuit breaker. This should immediately shut down the pool heater. If the circuit breaker does not shut off, you should call a professional service technician to come out and inspect the problem. Next, check the fuse box located near the pool pump. The fuses should be in good condition.Hayward - Inground Pool Heater - Universal H-Series - Lo-Nox. Categories. Above Ground Pool Packages; Above Ground Pool Liners . Above Ground Pool Liner Accessories ; ... Lo-Nox - Inground Pool … Hayward Universal H-Series H350 Low NOx Pool Heater, 350,000 BTU, Natural Gas - EXPERT LINE NLA ... H350FDN. SKU. 4075. Product Overview. Hayward H-series Pool Heater ... When your Hayward pool heater flashes the ‘bo code’, it’s signaling that there’s an issue with the bypass operation. Here’s a strategic approach to get your heater back to optimal functionality. Reset the Heater: Turn off the heater and the circuit breaker for 30 seconds. Power up the system again to see if the ‘bo code’ persists.Sep 15, 2020 ... Bad ribbon cable plus broken vacuum sensor hose and to top it all off, some critters found a nice cozy home! "CE" code is normally fixed by ...

With a little effort and knowledge, you can get your Hayward pool heater back up and running in no time. Also see: Hayward Heater LO Code Fixes. Or if you are in need of a new heater, check out these new models: Hayward W3H400FDN Universal H-Series 400,000 BTU Natural Gas Pool and Spa Heater for In-Ground Pools and Spas .. Difference between holosun 507c and 507k

hayward pool heater lo

TOP VENT PRO-INVERTER 13.5kW. SKU: PASRW030PUBP. Add to Compare. Showing 1-12 of 22. 1. 2. Heating swimming pools is a wise investment as it increases its value and extends the swimming season. So to graduate to a higher degree of comfort and control, choose a Hayward pool heater.The LO code on a Hayward heater means Limit Open, where one of the limit switches is not closing to complete the circuit. To clear the LO code, fix or replace the wiring on the …The Hayward Universal H-Series gas heater is one of the most energy-efficient Pool and Spa heating solutions on the market! ... Shop our wide selection of Hayward Pool Heaters; Return Policy; Product Information. Internet # 311793696. Model # HPPW3H150FDP. Store SKU # 1004869549. Additional ResourcesFirst, check the power source. Make sure the heater is properly plugged in and that the circuit breaker or fuse hasn’t tripped. Next, check the water flow. A low water flow can cause the heater to overheat and shut down. Check the pool pump and filter for any clogs or debris that could be restricting water flow.The Hayward pool heater spa mode is designed to maintain a specific “spa-like” temperature in the pool. To use this mode, enable “Spa mode” from the control panel, set the required temperature, and let the pool heater warm the water. Once ready, test the water. This process is a joy to behold for those who want to soak themselves in ...Hayward pool heaters can experience numerous problems. Here are some of the more common issues with pool heaters: Pool Heaters Not Working. If your pool heater isn’t …Hayward Pool heater LO errorThe Hayward heater LO code indicates a fault in the temperature limit switch, vent pressure switch, or water pressure switch. To fix it, ensure the pump is on, is wired and connected …Sep 24, 2019 · Problem Possible Cause Possible Solution; Heater cycles on & off: 1. Filter or pump baskets are dirty. 2. External bypass is out of adjustment. 3. Internal bypass is broken or stuck. HeatPro Series Heat Pump. Hayward. SKU: HP21405T. Our new HeatPro Series of Heat Pumps utilize industry-first microchannel technology to get your pool water to the perfect temperature. Add to Compare. Add to Export. Overview. Specifications.Nov 13, 2021 · My Hayward spa heater (installed 2018) is not heating the water and is displaying this LO code. I have read every troubleshooting guide and watched every video I could find. My diagnostics included: 1. Cleaned the filters, even ran the pump without the filters - still LO 2. Checked wires at pressure switch for continuity - still LO 3. Service LED ON: “LO” Code “LO” Code (Limit Open) may relate to water flow. Verify the pump is running & adequate water is flowing through heater. “LO” is NORMAL when the …Here you’ll gain easy access to information regarding your favorite Hayward products. Whether you are looking for a Quick Reference Guide, troubleshooting steps, or simply wish to view one of our product support videos, you have come to the right place.Pomeade IDXL2DB1930 Display Board Replacement for Hayward Heater IDXL2DB1930 Display Board, Compatible with Hayward Universal H-Series Low Nox Induced Draft Heater, H400FDN HD150FDN dummy Hayward W3H150FDP Universal H-Series 150,000 BTU Propane Pool and Spa Heater for In-Ground Pools and SpasMay 10, 2022 · 1. Hayward Pool Heater Service Light LO; 2. Hayward Pool Heater Service Light CE; 3. Hayward Pool Heater Service Light IF; 4. Hayward Pool Heater Service Light AO; 5. Hayward Pool Heater Service Light BD; FAQ: What are the Hayward pool heater lockout settings? How to reset Hayward pool heater? HeatPro Heat Pump 140k BTU. Hayward. SKU: HP21404TC. High performance, energy-efficient HeatPro heat pumps quietly and economically maintain the ideal water temperature at all times. Add to Compare. Add to Export. Overview. Specifications. The Hayward Universal H-Series gas heater is one of the most energy-efficient Pool and Spa heating solutions on the market! Its ground-breaking hydraulic design reduces pump circulation run time, giving you an energy savings of up to 18%! This unit is perfect for the environmentally conscious Pool and Spa owner thanks to its Low NOx capabilities.This quick video is a great resource for basic understanding of your Hayward gas heater..

Popular Topics